Option Mod. Space Description
J 1.5 Two (2) Circuit Solenoid Monitor &
R
elease Module w/Relays for 120 VAC
Solenoids
JJ 2.5 Two (2) Circuit Solenoid Monitor &
R
elease Module w/Relays for 250
VDC Solenoids
K 1.0 Audible Extender Module (2
C
ircuits/Module, Class A/B)
L—Built-in Alarm Indicating Sonalert
M 1.0 Auxiliary DPDT Alarm Relay, 10 amp
@ 120 VAC or 28 VDC
N 1.0 Auxiliary DPDT Trouble Relay, 10
amp @ 120 VAC or 28 VDC
P 1.0 HD 4 Pole Relay, Ratings to 600 VAC
and 240 VDC
Q 1.5 HD 6 Pole Relay, Ratings to 600 VAC
and 240 VDC
R 1.5 HD 8 Pole Relay, Ratings to 600 VAC
and 240 VDC
S 0.5 Time Delay Relay-Solid State .6 — 60
Seconds
T—External NEMA-4X Key Operated
Switches (Consists of Switches for
Lamp Test, Alarm Silence, Trouble/
Supervisory Silence & System Reset)
U—Battery Charging Meters (DC Volt and
Amp Meters)
V 1.5 Auxiliary FWR 5 amp Power Supply
(APS-1 w/ Transformer)
W 2.0 Auxiliary Regulated 7 amp Power
Supply w/ APS-1 Module
Step 4.
System Enclosures
To determine the proper size system enclosure, it is necessary to
calculate the total space required by all system components. Begin
by adding the number of module spaces required for the basic
control unit in Step 1, power input option from Step 2 and for the
quantity of each option selected in Step 3. The sum of these
numbers equals the total space required by the system you have
configured. Select an enclosure whose total space capacity exceeds
this number. If the total module spaces required for the system exceed
the size of the largest enclosure, a custom sized enclosure is required.
Consult the Factory.
Module
Model Description Space
• EHD4230 Industrial Type–NEMA 4 Rated 20
• EHD4236 Industrial Type–NEMA 4 Rated 28
• EHD4836 Industrial Type–NEMA 4 Rated 35
• EHD6036 Industrial Type–NEMA 4 Rated 45
System Enclosure Disclaimer
D
ue to the custom design features of the 2600HD Series and the
potential for system variations requiring ancillary devices not
accounted for by standard factory options, all 2600HD system
enclosures estimated and/or ordered using this information are
considered preliminary and are subject to change upon final
F
actory review.
Step 5. Finalize the complete system model number by listing the
configuration selected in Steps 1, 2, 3 and 4 in the same format as
s
hown in this example:
2600HD1-GC1-BEH2-EHD4230
Control unit with Protectowire Alarm Point Location Meter,
operating on 120 VAC, 50-60 Hz. input and gel cell battery
backup; (1) ZM-3224 Input Module (Option B) with four Class B
detection zones; (1) ZM-3224 Input Module (Option E) with four
Class B switch supervisory circuits; (2) RM-2 Solenoid Monitor &
Release Modules (Option H) (4 Release Circuits/2 per module) all
in a red EHD4230 NEMA-4 enclosure.
Step 6.
Each 2600HD Series Control Panel is custom assembled
and tested at the factory as a complete system. In order to ensure
conformance with each customer’s operating requirements, every
order must be accompanied by a brief description of the panel’s
operating logic and zone functions.
How To Order A 2600HD Extender
Panel
A. Select model number of basic 2600HD Extender Panel. Each
model requires 2 module spaces in the enclosure.
•
E2600HD1
— System Extender Panel for use with a
2600HD1 Control Panel containing a Protectowire Alarm
Point Location Meter.
•
E2600HD2
— System Extender Panel for use with a
2600HD2 Control Panel without a Protectowire Alarm
Point Location Meter.
•
E2600HD3
— System Extender Panel for use with a
2600HD3 Control Panel containing a Touch Screen PCLC
Graphic Display.
B. Select Option Code Letter(s) from those listed in Step 3 and
show quantity.
C. Determine the size of the extender’s enclosure by calculating the
total space required by all system components. Begin by adding
the number of module spaces required by the basic 2600HD
Extender Panel and for the quantity of each option selected.
The sum of these numbers equals the total space required by
the extender you have configured. Follow the procedure previ-
ously outlined in Step 4 to select the proper size enclosure.
D. Finalize complete 2600HD Extender Model Number as shown
in the example. Note that the quantity of each option ordered
is shown after its Option Code Letter.
E2600HD1-B2G4M8-EHD4230
DS 9165A-0106 (1M)